MIL-DTL-2/19D
SPECIAL REQUIREMENTS:
1. An eduction tube shall be supplied in accordance with figure 1 of this specification
sheet.
2. Mark the valve body: CARBOXIDE S.
OPTIONAL REQUIREMENTS:
1. Outlet cap or plug (required) (not required).
INTENDED USE: The valves covered by this specification sheet are intended for use with
cylinders for a mixture of 10 percent ethylene oxide and 90 percent carbon dioxide which is a
sterilization and fumigation agent known as Carboxide.
NOTES:
1. Special requirements will be mandatory for all valve procurements.
2. Optional requirements will be specified for each valve procurement.
CHANGES FROM PREVIOUS ISSUE: Marginal notations are not used in this revision to
identify changes with respect to the previous issue due to the extent of the changes.
2