RR-C-901E
TABLE IV. Valve identification designation - Continued.
Valve identification |
Former detail specification number1 |
A-A-59860 PIN |
Service pressure (psig) |
Gas service |
161 |
MIL-DTL-2/71 |
AA59860-161 |
2015 |
High pressure, toxic and oxidizing mixtures |
162 |
AA59860-162 |
2265 |
||
163 |
AA59860-163 |
2400 |
||
164 |
MIL-DTL-2/72 |
AA59860-164 |
0 - 3000 |
Fluorinating compound mixtures |
165 |
AA59860-165 |
|||
166 |
AA59860-166 |
|||
167 |
MIL-DTL-2/73 |
AA59860-167 |
0 - 500 |
Corrosive (basic) mixtures |
168 |
MIL-DTL-2/74 |
AA59860-168 |
0 - 500 |
Low pressure, toxic and oxidizing mixtures |
169 |
AA59860-169 |
|||
170 |
MIL-DTL-2/75 |
AA59860-170 |
3500 - 3600 |
Oxygen (non-medical) |
171 |
AA59860-171 |
4000 |
||
172 |
MIL-DTL-2/76 |
AA59860-172 |
1800 - 2400 |
Oxidizing mixtures |
173 |
AA59860-173 |
1800 |
||
174 |
AA59860-174 |
2015 |
||
175 |
AA59860-175 |
2265 |
||
176 |
AA59860-176 |
2400 |
||
177 |
MIL-DTL-2/77 |
AA59860-177 |
225 |
Methyl chloride |
178 |
AA59860-178 |
240 |
||
179 |
AA59860-179 |
300 |
||
180 |
AA59860-180 |
225 |
||
181 |
AA59860-181 |
240 |
||
182 |
AA59860-182 |
300 |
||
999 |
None |
Plug |
- |
- |
1 The former detail specification number is given for cross-reference purposes only.
TABLE V. Cylinder defects.
Defect |
Major |
Minor |
Dimensions not as specified |
101 |
- |
Construction not as specified |
102 |
- |
Cleaning not as specified |
103 |
- |
Markings not as specified |
- |
201 |
Delivery date not within one year of the test date |
- |
202 |
Treatment and painting not as specified |
- |
203 |
Workmanship not as specified |
- |
204 |