MIL-DTL-11732F
MASTER PAINTERS INSTITUTE
MPI #9
- Alkyd, Exterior Gloss (MPI Gloss Level 6)
(Copies of this document are available online at https://www.paintinfo.com/ or from Master Painters
Institute, 2800 Ingleton Avenue, Burnaby, BC V5C 6G7 Canada.)
SSPC: THE SOCIETY FOR PROTECTIVE COATINGS
SSPC-Paint 25
- Zinc Oxide, Alkyd, Linseed Oil Primer for Use
Over Hand Cleaned Steel Type I and Type II
SSPC-SP 5
- White Metal Blast Cleaning
SSPC-SP 6
- Commercial Blast Cleaning
SSPC-SP 10
- Near-White Metal Blast Cleaning
(Copies of these documents are available online at https://www.sspc.org/ or from SSPC: The
Society for Protective Coatings, 40 24th Street, Sixth Floor, Pittsburgh, PA 15222.)
2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event
of a conflict between the text of this document and the references cited herein, the text of this
document takes precedence. Nothing in this document, however, supersedes applicable laws and
regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 Configuration. Cylinders shall conform to the requirements of 49 CFR 178.36 for
DOT 3A or 49 CFR 178.37 for DOT 3AA, and shall be as specified herein.
3.1.1 Cylinders. The cylinder shall be as specified in table I. All dimensions are in
inches. The tolerance for outside diameter (OD) is ±0.5 inch and that for height is ±2 inches.
TABLE I. Cylinder configuration.
Type
Nominal gas
Min. water
Max. tare
Outside dimensions
capacity
capacity
weight
OD
Height
(pounds)
(pounds)
(pounds)
(inches)
(inches)
I
20
6
19
16
25
II
30
6
29
24
35
III
100
8.5
48
80
85
IV
150
10.25
48
120
120
3.1.2 Flanges, valves, and caps. The cylinder shall be supplied with flanges, valves and
cap in accordance with 3.4 and figure 1.
4